Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the all-in-one-wp-security-and-firewall domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/rstechnics/domains/wp.rstechnics.nl/public_html/wp-includes/functions.php on line 6114
LCD – RS Technics BV

TM16 – Temperature Monitor for 16 channels

icon-tm16-temperature-monitor

icon-tm16-temperature-monitor

The TempMonitor-16 is the solution for displaying and monitoring a maximum of 16 measurement signals on 1 central display unit. By means of the push buttons the desired measurement value can be shown on the display, and the settings for the monitoring contact can be changed.

DESCRIPTION

The TempMonitor-16 is a compact monitor unit specially developed for simultaneously monitoring a maximum of 16 measurement signals. The TempMonitor-16 has two alarm contacts. The alarm function can be set separately for each measurement channel. By means of the LCD display and the push buttons on the front the measurement value of each channel can be displayed. If an alarm is given the measurement value of the channel in question is automatically displayed and a notification follows with the Relay contact and indication via LED and internal acoustic Buzzer. Fail-safe alarm contact with detection of sensor faults. This unit is intended for panel installation.

SPECIFICATIONS
Types TM16: Temperatur Monitor with 16 inputs.
Description Programmable 16-channel temperature monitor in housing for panel installation NG144x72mm. LCD-display 2×16 characters with background lighting. 2 Alarm relay max. 3 Amp @ 250 VAC. All connections with screw/insert connectors. Supplied including connection and mounting materials.
Possible applications
  • Industrial applications.
  • Process control.
  • Shipping.
  • Machine construction.
Measurement system As requested with order:

  • PT100 – IEC60751/3-lead
  • Thermocouple J or K
  • Voltage 0-10VDC
  • Current 4-20 mA
Measurement range Available measuring inputs, all 16 channels are in the same range:

  • PT100: -50…+200 °C and 0…600 °C.
  • Thermocouple-J: 0…500 °C.
  • Thermocouple-K: 0…1200 °C.
  • Current: 0…100 °C, Display range adjustable.
  • Voltage: 0…100 °C, Display range adjustable
Outputs Two relay contacts, potential-free contact N.O., max. 3 Amp @ 250 VAC.
Power Standard 230 VAC – 50/60 Hz, optional in 24 VDC.
Accuracy ± 1% FSR.
IP-norm IP54 (front/panel side).
Dimensions Panel installation 144×72, depth 110 mm.
Options (for supplement)
  • Front plate with own logo, company name or measurement unit
  • Installed in a cabinet or housing for wall mounting
DOCUMENTATION

• Brochure
• Manual and connection diagram

ORDERING

The delivery of standard types from stocks and customer-specific versions can be within a few days.In view of the large number of versions and options for orders you can contact our sales department tel. +31 50-501 37 45 or by email:
sales@rstechnics.nl

LB08 Milk tank monitor

icon-lb08-dairy-tank monitor

icon-lb08-dairy-tank monitor

High quality data logger and control unit for monitoring the milk stored in the dairy tank. 

DESCRIPTION

RS Technics has been developing and manufacturing control equipment for use in the tank rooms of dairy farmers all over the world. The dairy monitoring of our company is well-known amongst farmers and dairy processing plants. With the latest addition from this family, the LB-08: Dairy Tank Monitor, a financially-friendly alternative has been introduced that has all the properties necessary to constantly monitor the quality of the milk. By means of accurate measurements on the outside of the tank or inside the tank, the LB-08 can measure the current temperature of the milk, detect the correct operation of the mixing gear, check the cleaning and sound an alarm as soon as a problem threatens to occur. In addition to an internal buzzer this tank monitor has an adjustable relay output for an external alarm. The LB-08 collects all measurement data and stores this in the internal memory (capacity of approx. 50,000 measurements). This data can be transferred to a laptop or PC via a USB connection and presented in graphs or clear tables. Although the LB-08 has been primarily developed for use in the dairy processing industry, this can of course be modified according to the specific requirements of customers for the monitoring of numerous other products stored in tanks. Please feel free to ask for more information or indicate your application!

Principle:
The tank monitor works normally via a fixed control pattern:

  • status MILKING
  • there is milk in the tank and new milk can be added. This can therefore take a few days.

  • status TANK EMPTY BEFORE CLEANING
  • Tank is empty and still has to be cleaned.

  • status CLEANING
  • Tank is filled with water and cleaning agent; busy with cleaning.

  • status TANK EMPTY AFTER CLEANING
  • Tank empty; ready for new milk.

All these things are accurately and constantly monitored whereby undesired deviations are indicated and converted into a clear alarm!

SPECIFICATIONS
Types
  • LB08-2:Tank monitor with 2 measurement inputs, monitors the milk tank.
  • LB08-3: Dairy Monitor 3 inputs, monitors the milk tank and cleaning.
Description
  • High quality data logger and control unit for monitoring dairy and other liquids in the storage tanks.
  • Status notification via 5 red/green indication LEDs and alarm via flashing LED indication and buzzer.
  • Connection via internal screw connectors.
  • Front plate with push buttons and display LCD white/blue with background lighting.
  • USB connection for setting and reading out via computer.
  • Light grey ABS housing (UL94V-0), wall mounting with screws.
Possible applications
  • Dairy processing industry.
  • Milk tanks, RMO.
  • Applications in monitoring tank storage.
Measurement system PT100-IEC60751/3L sensor for internal or external measurement on the tank.
Measurement range -10…+90 °C
Outputs
  • 1 Relay contact, N.O. max. 3 Amp.@ 250VAC.
  • auxiliary voltage 12 VDC, max. 100 mA, for alarms.
Power Universal 80-240VAC – 50/60 Hz
Accuracy ± 1% FSR
IP-norm IP65
Dimensions (lxwxd): 160 x 130 x 60 mm excl. swivels and cables.
Options (for supplement)
  • Software adjustments for control and alarm parameters etc.
  • OEM version fitted with your own front plate print.
DOCUMENTATION

• Brochure LB08 (Dutch)
• Brochure LB08 (German)
• Brochure LB08 (English)

ORDERING

The delivery of standard types from stocks and customer-specific versions can be within a few days. In view of the large number of versions and options for orders you can contact our sales department tel. +31 50-501 37 45 or by email:
sales@rstechnics.nl